General Data of the Residential Storage Inverter HYD 3~6K-EP

  1. Dimensions (W*H*D): 482*503*183mm
  2. Weight: 21.5kg
  3. Operating temperature range: 30℃~+60℃ (Above 45℃ derating)
  4. Relative humidity range: 5%~95%
  5. Max. operating altitude: 4000m
  6. Standby self-consumption [2]: <10W
  7. Topology: High frequency isolation (for battery)
  8. Installation method: Wall-mounted
  9. Degree of protection: IP65
  10. Cooling mode: Natural
  11. Communication: RS485/CAN/WiFi, Optional: Ethernet/4G
  12. Display: LCD & APP+Bluetooth
  13. Standard: EN 61000-6-2, EN 61000-6-3, EN 61000-3-2, EN 61000-3-3, EN 61000-3-11, EN 61000-3-12, IEC 62109-1/2, IEC 62040-1, IEC 62116, IEC 61727, IEC 61683, IEC 60068(1,2,14,30), VDE-AR-N 4105, VDE V 0126-1-1, AS/NZS 4777, CEI 0-21, G98/G99, TR321,TR322, EN 50438/EN50549, UTE C15-712-1, NRS 097-2-1, UNE 206 007-1

Datasheet HYD 3000-EP HYD 3680-EP HYD 4000-EP HYD 4600-EP HYD 5000-EP HYD 5500-EP HYD 6000-EP
DC input (PV)
Recommended max.PV input power 4500Wp 5400Wp 6000Wp 6900Wp 7500Wp 7500Wp 9000Wp
Max. input voltage 600V 600V 600V 600V 600V 600V 600V
Start-up voltage 100V 100V 100V 100V 100V 100V 100V
Rated input voltage 360V 360V 360V 360V 360V 360V 360V
MPPT operating voltage range 90-550V 90-550V 90-550V 90-550V 90-550V 90-550V 90-550V
Number of MPPT 2 2 2 2 2 2 2
Max. number of input strings per MPPT 1/1 1/1 1/1 1/1 1/1 1/1 1/1
Max. input current per MPPT 13A/13A 13A/13A 13A/13A 13A/13A 13A/13A 13A/13A 13A/13A
Max. short-circuit current per MPPT 18A/18A 18A/18A 18A/18A 18A/18A 18A/18A 18A/18A 18A/18A
Ac output (on-grid)
Rated output power 3000W 3680W 4000W 4600W 5000W 5000W 6000W
Rated output current 13A 16A 17.4A 20A 21.7A 23.9A 26.1A
Rated grid voltage L/N/PE, 230V L/N/PE, 230V L/N/PE, 230V L/N/PE, 230V L/N/PE, 230V L/N/PE, 230V L/N/PE, 230V
Rated grid frequency 50/60Hz 50/60Hz 50/60Hz 50/60Hz 50/60Hz 50/60Hz 50/60Hz
Max. output apparent power 3000VA 3680VA 4000VA 4600VA 5000VA 5000VA 6000VA
Max.output current 15A 16A 20A 20.9A 21.7A 25A 27.3A
THDi <3% <3% <3% <3% <3% <3% <3%
Power factor 1 (adjustable +/-0.8)
Battery parameters
Battery type Lithium-ion, Lead-acid[3]
Battery voltage range 42-58V 42-58V 42-58V 42-58V 42-58V 42-58V 42-58V
Number of battery input channels 1 1 1 1 1 1 1
Max.charge/discharge power 3750W 4000W 4250W 5000W 5000W 5000W 5000W
Max.charge/discharge current 75A 80A 85A 100A 100A 100A 100A
BMS communication mode CAN, RS485 CAN, RS485 CAN, RS485 CAN, RS485 CAN, RS485 CAN, RS485 CAN, RS485
AC output (off-grid)
Rated output power 3000W 3680W 4000W 4600W 5000W 5000W 5000W
Rated output current 13A 16A 17.4A 20A 21.7A 23.9A 26.1A
Rated output voltage L/N/PE, 230V L/N/PE, 230V L/N/PE, 230V L/N/PE, 230V L/N/PE, 230V L/N/PE, 230V L/N/PE, 230V
Rated output frequency 50/60Hz 50/60Hz 50/60Hz 50/60Hz 50/60Hz 50/60Hz 50/60Hz
Max. output apparent power 3000VA 3680VA 4000VA 4600VA 5000VA 5000VA 5000VA
Peak output apparent power, time 4500VA, 30s 4800VA, 30s 5100VA, 30s 6000VA, 30s 6000VA, 30s 6000VA, 30s 6000VA, 30s
Max.output current 13.6A 16A 18.2A 20.9A 22.7A 22.7A 22.7A
THDv(@linear load) <3% <3% <3% <3% <3% <3% <3%
Switching time 10ms default 10ms default 10ms default 10ms default 10ms default 10ms default 10ms default
Efficiency
Max.MPPT efficiency 99.9% 99.9% 99.9% 99.9% 99.9% 99.9% 99.9%
Max.efficiency 97.6% 97.6% 97.6% 97.8% 97.8% 97.8% 98%
European efficiency 97.2% 97.2% 97.2% 97.3% 97.3% 97.3% 97.5%
Max.efficiency of charging/discharging [1 ] 94.6% 94.6% 94.6% 94.6% 94.6% 94.6% 94.6%
Protection
DC switch Yes Yes Yes Yes Yes Yes Yes
PV reverse connection protection Yes Yes Yes Yes Yes Yes Yes
Battery reverse connection protection Yes Yes Yes Yes Yes Yes Yes
Output short circuit protection Yes Yes Yes Yes Yes Yes Yes
Output overcurrent protection Yes Yes Yes Yes Yes Yes Yes
Output overvoltage protection Yes Yes Yes Yes Yes Yes Yes
Insulation impedance detection Yes Yes Yes Yes Yes Yes Yes
Residual current detection Yes Yes Yes Yes Yes Yes Yes
Anti-island protection Yes Yes Yes Yes Yes Yes Yes
Surge protection PV: Type III, AC: Type III