Features of SUNGROW Solar Inverter
High yield
- Up to 5 MPPTs with max. efficiency 98.7%
- Compatible with bifacial modules
- Built-in PID recovery function
Smart O&M
- Touch free commissioning and remote firmware upgrade
- Online IV curve scan and diagnosis*
- Fuse free design with smart string current monitoring
Low cost
- Compatible with Al and Cu AC cables
- DC 2 in 1 connection enabled
- Cable free communication with optional WLAN
Proven safety
- IP66 and C5 protection
- Type II SPD for both DC and AC, DC Type I+II Opt
- Satisfied global safety and grid code
CIRCUIT DIAGRAM
EFFICIENCY CURVE
SIZE
Type designation | SG33CX | SG40CX | SG50CX |
Dimensions (W*H*D) | 702*595*310mm | 782*645*310mm | 782*645*310mm |
Weight | 50kg | 58kg | 65kg |
lnput (DC)
Type designation | SG33CX | SG40CX | SG50CX |
Max.PV input voltage | 1100V* | 1100V* | 1100V* |
Min. PV input voltage / start-up input voltage | 200V/250V | 200V/250V | 200V/250V |
Nominal PV input voltage | 585V | 585V | 585V |
MPP voltage range | 200-1000V | 200-1000V | 200-1000V |
No. of independent MPP inputs | 3 | 4 | 5 |
No. of PV strings per MPPT | 2 | 2 | 2 |
Max.PV input current | 3*26A | 4*26A | 5*26A |
Max.DC short-circuit current | 3*40A | 4*40A | 5*40A |
Output (AC)
Type designation | SG33CX | SG40CX | SG50CX |
AC output power | 33 KVA @45ºC, 400Vac / 36.3 KVA @ 40ºC, 400Vac
33 KVA @ 50ºC, 415Vac / 36.3 KVA @ 45ºC, 415Vac |
40 KVA @45ºC, 400Vac / 44 KVA @ 40ºC, 400Vac
40 KVA @ 50ºC, 415Vac / 44 KVA @ 45ºC, 415Vac |
50 KVA @45ºC, 400Vac / 55 KVA @ 40ºC, 400Vac
50 KVA @ 50ºC, 415Vac / 55 KVA @ 45ºC, 415Vac |
Max.AC output current | 55.2A | 66.9A | 83.6A |
Nominal AC voltage | 3 / N / PE, 230 / 400 V | 3 / N / PE, 230 / 400 V | 3 / N / PE, 230 / 400 V |
AC voltage range | 312 – 528 V | 312 – 528 V | 312 – 528 V |
Nominal grid frequency / Grid frequency range | 50 Hz / 45 – 55 Hz, 60 Hz / 55 – 65 Hz | 50 Hz / 45 – 55 Hz, 60 Hz / 55 – 65 Hz | 50 Hz / 45 – 55 Hz, 60 Hz / 55 – 65 Hz |
Harmonic (THD) | <3%(at nominal power) | <3%(at nominal power) | <3%(at nominal power) |
DC current injection | < 0.5 % In | < 0.5 % In | < 0.5 % In |
Power factor at nominal power / Adjustable power factor | > 0.99 / 0.8 leading – 0.8 lagging | > 0.99 / 0.8 leading – 0.8 lagging | > 0.99 / 0.8 leading – 0.8 lagging |
Feed-in phases / AC connection | 3/3 | 3/3 | 3/3 |
Max.efficiency / European efficiency | 98.6 % / 98.3 % | 98.6 % / 98.3 % | 98.7 % / 98.4 % |
Protection
DC reverse polarity protection | Yes |
AC short circuit protection | Yes |
Leakage current protection | Yes |
Grid monitoring | Yes |
Ground fault monitoring | Yes |
DC switch | Yes |
AC switch | Yes |
PV string monitoring at night function | Yes |
PID recovery function | Yes |
Arc fault circuit interrupter (AFCI) | Optional |
Overvoltage protection | DC Type II (optional: Type I + II) / AC Type II |
*: Only compatible with Sungrow logger, EyeM4 and iSolarCloud