Goodwe Hybrid Inverter Solar ES Series 3KW To 6KW With 97.6% Working Efficiency


ES G2 series bidirectional energy storage inverters can meet the needs of photovoltaic and energy storage systems at the same time. It can not only realize grid-connected and off-grid functions, but also realize bidirectional control of electric energy, intelligent control, and highly autonomous energy scheduling.

$1,187.00

Compare
Inverter Technical Data
GW3000/3600/5000/6000-ES-20
Battery Input Data
Battery Type
Li-Ion
Nominal Battery Voltage (V)
48
Battery Voltage Range (V)
40 ~ 60
Max. Continuous Charging Current (A)
60
75
60
120
60
120
60
Max. Continuous Discharging Current (A)
60
75
60
120
60
120
60
Max. Charge Power (W)
3000
3600
3000
5000
3000
6000
3000
Max. Discharge Power (W)
3200
3900
3200
5300
3200
6300
3200
PV String Input Data
Max. Input Power (W)
4500
5400
5400
7500
7500
9000
9000
Max. Input Voltage (V)
600
MPPT Operating Voltage Range (V)
60 ~ 550
Start-up Voltage (V)
58
Nominal Input Voltage (V)
360
Max. Input Current per MPPT (A)
16
Max. Short Circuit Current per MPPT (A)
23
Number of MPP Trackers
1
Number of Strings per MPPT
1
AC Output Data (On-grid)
Nominal Apparent Power Output to Utility Grid (VA)
3000
3680
3680
5000*3
5000*3
6000*3
6000*3
Max. Apparent Power Output to Utility Grid (VA)
3000
3680
3680
5000*3
5000*3
6000*3
6000*3
Max. Apparent Power from Utility Grid (VA)
6000
7360
3680
10000
5000*3
10000
6000*3
Nominal Output Voltage (V)
220 / 230 / 240
Nominal AC Grid Frequency (Hz)
50 / 60
Max. AC Current Output to Utility Grid (A)
13.6
16.7
16.7
22.7
22.7
27.3
27.3
Max. AC Current From Utility Grid (A)
27.3
33.5
16.7
43.5
22.7
43.5
27.3
Power Factor
~1 (Adjustable from 0.8 leading to 0.8 lagging)
Max. Total Harmonic Distortion
<3%
AC Output Data (Back-up)
Back-up Nominal Apparent Power (VA)
3000
3680
3680
5000
5000
6000
6000
Max. Output Apparent Power (VA)
3000 (6000@10sec)
3680 (7360@10sec)
3680
5000 (10000@10sec)
5000
6000 (10000@10sec)
6000
Max. Output Current (A)
13.6
16.7
16.7
22.7
22.7
27.3
27.3
Nominal Output Voltage (V)
220 / 230 / 240
Nominal Output Freqency (Hz)
50 / 60
Output THDv (@Linear Load)
<3%
Efficiency
Max. Efficiency
97.6%
European Efficiency
96.7%
Max. Battery to AC Efficiency
95.5%
MPPT Efficiency
99.9%
Protection
PV String Current Monitoring
Integrated
PV Insulation Resistance Detection
Integrated
Residual Current Monitoring
Integrated
PV Reverse Polarity Protection
Integrated
Anti-islanding Protection
Integrated
AC Overcurrent Protection
Integrated
AC Short Circuit Protection
Integrated
AC Overvoltage Protection
Integrated
DC Switch
Integrated
DC Surge Protection
Type II
AC Surge Protection
Type II
AFCI
Optional
Remote Shutdown
Integrated
General Data
Operating Temperature Range (°C)
-25 ~ +60
Relative Humidity
0 ~ 95%
Max. Operating Altitude (m)
3000 (>2000 Derating)
Cooling Method
Natural Convection
Display
LED, WLAN + APP
Communication with BMS
CAN
Communication with Meter
RS485
Communication with Portal
WiFi / WiFi + LAN / 4G
Weight (kg)
19.6
20.8
20.0
21.5
20.0
21.5
20.0
Dimension (W × H × D mm)
505.9 × 434.9 × 154.8
Topology
Non-isolated
Self-consumption at Night (W)
<10
Ingress Protection Rating
IP65
Mounting Method
Wall Mounted
Specification

530w, 535w, 545w

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Goodwe Hybrid Inverter Solar ES Series 3KW To 6KW With 97.6% Working Efficiency”

There are no reviews yet.