Hybrid Inverter Model
|
BluE-S 3680D
|
BluE-S 5000D
|
PV String Input
|
||
Max. DC Input Power (W)
|
4800
|
6500
|
Max. DC Input Voltage (V)
|
580
|
580
|
Nominal voltage (V)
|
400
|
400
|
MPPT voltage range
|
120V-550V
|
120V-550V
|
Startup voltage
|
130V
|
130V
|
MPPT voltage range at full load
|
184~550V
|
184~550V
|
Number of MPPT
|
2
|
2
|
No. of Strings per MPPT
|
1
|
1
|
Max. input current per MPPT
|
13A
|
13A
|
Max. short-circuit current per MPPT
|
16A
|
16A
|
AC Output (Grid)
|
||
Nominal AC output power
|
3680W
|
4999W
|
Max. AC apparent power
|
7360VA(from grid)
|
7360VA(from grid)
|
Maximum AC output power
|
3680W
|
4999W
|
Nominal AC voltage
|
230Vac
|
230Vac
|
AC grid frequency range
|
50 / 60Hz±5Hz
|
50 / 60Hz±5Hz
|
Max. output current
|
16A
|
16A
|
Max. input current
|
32A
|
32A
|
Power factor (cosΦ)
|
0.8leading-0.8lagging
|
0.8leading-0.8lagging
|
THDi
|
<3%
|
<3%
|
Battery Input
|
||
Battery Type
|
LFP (LiFePO4)
|
LFP (LiFePO4)
|
Nominal Battery Voltage
|
51.2V
|
51.2V
|
Max. Charging Voltage
|
57.6V
|
57.6V
|
Max. Charging Current
|
50A
|
100A
|
Max. Discharging Current
|
80A
|
100A
|
Battery Capacity
|
100-400Ah
|
100-400Ah
|
Charging Strategy for Li-Ion Battery
|
Depend on the BMS
|
Depend on the BMS
|
AC Output (Backup)
|
||
Max. Output Apparent Power
|
4000VA
|
4000VA
|
Peak Output Apparent Power
|
6900VA 10sec
|
6900VA 10sec
|
Max. Output Current
|
16A
|
16A
|
Nominal Output Voltage
|
230±0.2%
|
230±0.2%
|
Nominal Output Freqency
|
50/60Hz±0.2%
|
50/60Hz±0.2%
|
Output THDv (@Linear Load)
|
<2%(Linear load)/<2%
|
<2%(Linear load)/<2%
|
Efficiency
|
||
Max. PV Eciency
|
97.60%
|
97.60%
|
Euro. PV eciency
|
97.00%
|
97.00%
|
Max. Battery to Load Eciency
|
94.00%
|
94.00%
|
Battery charged by PV Max. Eciency
|
98.00%
|
98.00%
|
Protection
|
||
DC switch
|
Bipolar DC Switch (125A/Pole)
|
Bipolar DC Switch (125A/Pole)
|
Anti-islanding protection
|
Yes
|
Yes
|
Output over current
|
Yes
|
Yes
|
DC reverse polarity protection
|
Yes
|
Yes
|
String fault Detection
|
Yes
|
Yes
|
AC/DC surge protection
|
DC Type II;AC Type III
|
DC Type II;AC Type III
|
Insulation detection
|
Yes
|
Yes
|
AC short circuit protection
|
Yes
|
Yes
|
General Specifications
|
||
Dimensions W x H x D (mm)
|
540*640*240
|
|
Weight(kg)
|
32
|
|
Operating temperature range
|
0℃~+55℃(Charging)/-20℃~+55℃(DisCharging)
|
|
Noise (dB)
|
<25
|
|
Cooling type
|
Natural Convection
|
|
Max. operation altitude
|
≤2000m
|
|
Max. operation humidity
|
0~95% (No condensation)
|
|
IP class
|
IP65
|
|
Topology
|
Battery Isolation
|
|
Communication
|
RS485/CAN2.0/WIFI
|
|
Display
|
LCD/APP
|
|
Certifcation & Standard
|
AS/NZS 4777.2; CEI 0-16; IEC/EN 62109-1&2, IEC62040-1; IEC62116;IEC61727;
EN61000-6-1, EN61000-6-2, EN61000-6-3, EN61000-6-4,EN61000-4-16, EN61000-4-18, EN61000-4-29
|
Safety:
CATL LP Battery,stable and safe.
Module,pack,system,triple protection.
ip65,outdoor installation,away from living zoon.
Simple:
Modular design,single person can carry and install it.
Plug and play,30 min quick installation
Space saving;0.15 sq installation
Interconnection:
Global cloud platorm & Mobile APP,
anytime and any where.
Open API, Support power internet applications