Product introduction of Industrial Reverse Osmosis System
Industrial reverse osmosis system is an advanced membrane-based water treatment solution widely used in industrial water purification and boiler feed systems. The system combines pretreatment filtration, high-pressure membrane separation, and post-treatment sterilization to produce ultra pure water.
Through quartz sand filtration, activated carbon adsorption, water softening, precision filtration, and reverse osmosis membrane separation, impurities such as suspended solids, chlorine, hardness ions, dissolved salts, bacteria, and viruses are effectively removed. The final UV sterilization ensures safe and stable water quality.


Working principle
Step 1: Pretreatment System
Removes suspended solids, chlorine, and hardness to protect membrane.
Step 2: High Pressure Pump
Provides pressure to drive water through RO membrane system.
Step 3: Reverse Osmosis Filtration
Membrane separates dissolved salts, heavy metals, and microorganisms.
Step 4: UV Sterilization
Final disinfection ensures safe and bacteria-free water output.
Product Parameter Table
| Productivity | 50000 L/h |
| Weight | 500 kg |
| Power | 7 kW |
| RO membrane | VONTRON |
| Recovery rate | 60-65% |
| Pretreatment | Quartz sand/activated carbon/water softener/PP filter |
| Raw water TDS | <2000 ppm |
| Chemical dosing system | Anti-scale dosing |
| Pump | CNP or Optinal |
| Power supply | 380 V,50 Hz,3phase(if special, can customize) |
| Desalination rate | 97–99% |
| Operating pressure | 0.8–1.6 MPa |


Comparison With Other Technologies
| Technology | Filtration Accuracy | Chemical Use | Application |
|---|---|---|---|
| reverse osmosis system | very high | none | high purity water |
| ultrafiltration system | medium | none | pretreatment |
| EDI system | very high | none | ultrapure polishing |
| ion exchange | high | required | softening |
Main Features
- Multi-stage filtration system ensures deep purification and stable water quality
- RO membrane removes up to 99.9% dissolved solids and microorganisms
- Pretreatment system extends membrane life and reduces fouling risk
- High recovery rate of 60–70% improves water utilization efficiency
- Suitable for raw water TDS below 2000 ppm
- UV sterilization provides chemical-free final disinfection
- Automatic dosing system protects membrane performance
- Compact modular design for flexible installation
- Low operating cost and reduced maintenance requirements
- Continuous operation for industrial and commercial water systems


Application Scenarios
Industrial reverse osmosis system is widely used in the following water treatment applications:
- Reverse osmosis system for boiler feed water treatment to reduce scaling and corrosion
- Industrial RO system for high TDS water purification in manufacturing processes
- Reverse osmosis water treatment for drinking water production plants
- RO system for food and beverage processing water purification
- Industrial reverse osmosis system for pharmaceutical water treatment systems
- RO system for electronics and semiconductor ultra pure water production
- Reverse osmosis system for hotel and commercial building water supply
- Industrial RO system for agricultural irrigation and water reuse
- Reverse osmosis system for wastewater reuse and recycling applications
- RO system for laboratory and high purity water treatment systems


How to Choose Industrial Reverse Osmosis System
- Determine required capacity (m³/h or L/h)
- Check raw water TDS level
- Evaluate required water purity level
- Select appropriate membrane type (4040 / 8040)
- Consider recovery rate and operating cost
- Choose automatic control level (PLC / manual)
FAQ
1. What is industrial reverse osmosis system used for in boiler water treatment?
It is used to remove dissolved salts and impurities to produce high purity boiler feed water.
2. How to choose industrial reverse osmosis system capacity for factory use?
Capacity depends on daily water demand, raw water quality, and required output water purity.
3. What is the cost of industrial reverse osmosis system for water treatment?
Cost varies based on capacity, membrane type, and system configuration.
4. What is the difference between reverse osmosis and ultrafiltration system?
RO removes dissolved salts, while UF mainly removes suspended solids and larger particles.
5. Can reverse osmosis system remove heavy metals and bacteria effectively?
Yes, it removes up to 99.9% of heavy metals, bacteria, and dissolved contaminants.
6. What is the maintenance requirement of industrial RO system?
It includes membrane cleaning, filter replacement, and periodic system inspection.
7. Who is a reliable industrial reverse osmosis system supplier or manufacturer?
A reliable supplier provides customized design, technical support, and long-term service.
8. What raw water conditions are suitable for reverse osmosis system?
It is suitable for water with TDS below 2000 ppm after proper pretreatment.


Contact us to get your quotation now.
Get in touch with our engineering team.







